IT인증,IT자격증,IT자격증시험,IT인증시험

http://www.pass4test.net/

HP HP0-S34 (Implementing HP Rack and Tower Server Solutions) 덤프공부가이드

HP HP0-S34 (Implementing HP Rack and Tower Server Solutions) 시험에 도전해보려고 없는 시간도짜내고 거금을 들여 학원을 선택하셨나요? 사실 IT인증시험은 보다 간단한 공부방식으로 준비하시면시간도 돈도 정력도 적게 들일수 있습니다. 그 방법은 바로 Pass4Test의  HP HP0-S34 (Implementing HP Rack and Tower Server Solutions) 시험준비덤프자료를 구매하여 공부하는 것입니다. 문항수도 적고 시험예상문제만 톡톡 집어 정리된 덤프라 시험합격이 한결 쉬워집니다.

 

 

NO.1 After configuring the bare metal HP Agentless Management, the customer notices that not all

system information is display. In addition, to system information displayed with the bare metal

method, which information can be collected when running HP Agentless Management. (Choose

Two)

A. Storage firmware

B. Network firmware

C. Power an cooling information

D. Processor data

E. Memory information

Answer: C,E

 

NO.2 A customer wants to build an HPC cluster and needs the highest performance and bandwidth.

What should he used?

A. Flex 10

B. 10 GB Ethernet

C. Flex Fabric

D. FDR InfiniBand

Answer: D

 

NO.3 You are installing HP insight Control for Microsoft system Center on a customer site. You want

to

be able to use System Center Configuration Manager to install HP ProLiant drivers and firmwares

using a rules based model. Which component should be installed?

A. HP Proliant Pro Management Kit

B. HP Proliant Update Catalog

C. HP Proliant OS deployment Toolkit

D. HP Proliant Agent less Management Kit

Answer: B

 

NO.4 In HP Systems Insight Manager version 7 and beyond, which new tools can be used for

baselining? (Select two)

A. Track software and firmware versions

B. Manage software and firmware baselines

C. Manage hardware and software versions

D. Track hardware and software baselines

E. Track driver and firmware baselines

Answer: A,B

 

NO.5 You are planning to install an HP DL380 Gen8 server at a customer site. The customer wants to

use the HP Agentless management functionality. Which statement is correct when implementing

this management solution?

A. Pre-failure alerts can be configured for memory and drives

B. Redundancy status alerts can be configured for the CPU and the Smart Array controller

C. Redundancy status alerts can be configured for fans and the Smart Array controller

D. Pre-failure alerts can be configured for the CPU and the Smart Array controller

Answer: A

 

NO.6 Witch feature provides a customer alert to prevent a counterfiet hard drive from getting

installed in

an HP Proliant Gen8 server?

A. Drive error log NVRAM

B. Smart carrier authentication

C. Enhanced display

D. Smart array advanced pack

Answer: B

 

 
Posted 2013/5/30 6:34:55  |  Category: 미분류  |  Tag: