HP HP0-S34 (Implementing HP Rack and Tower Server Solutions) 시험에 도전해보려고 없는 시간도짜내고 거금을 들여 학원을 선택하셨나요? 사실 IT인증시험은 보다 간단한 공부방식으로 준비하시면시간도 돈도 정력도 적게 들일수 있습니다. 그 방법은 바로 Pass4Test의 HP HP0-S34 (Implementing HP Rack and Tower Server Solutions) 시험준비덤프자료를 구매하여 공부하는 것입니다. 문항수도 적고 시험예상문제만 톡톡 집어 정리된 덤프라 시험합격이 한결 쉬워집니다.
NO.1 After configuring the bare metal HP Agentless Management, the customer notices that not all
system information is display. In addition, to system information displayed with the bare metal
method, which information can be collected when running HP Agentless Management. (Choose
Two)
A. Storage firmware
B. Network firmware
C. Power an cooling information
D. Processor data
E. Memory information
Answer: C,E
NO.2 A customer wants to build an HPC cluster and needs the highest performance and bandwidth.
What should he used?
A. Flex 10
B. 10 GB Ethernet
C. Flex Fabric
D. FDR InfiniBand
Answer: D
NO.3 You are installing HP insight Control for Microsoft system Center on a customer site. You want
to
be able to use System Center Configuration Manager to install HP ProLiant drivers and firmwares
using a rules based model. Which component should be installed?
A. HP Proliant Pro Management Kit
B. HP Proliant Update Catalog
C. HP Proliant OS deployment Toolkit
D. HP Proliant Agent less Management Kit
Answer: B
NO.4 In HP Systems Insight Manager version 7 and beyond, which new tools can be used for
baselining? (Select two)
A. Track software and firmware versions
B. Manage software and firmware baselines
C. Manage hardware and software versions
D. Track hardware and software baselines
E. Track driver and firmware baselines
Answer: A,B
NO.5 You are planning to install an HP DL380 Gen8 server at a customer site. The customer wants to
use the HP Agentless management functionality. Which statement is correct when implementing
this management solution?
A. Pre-failure alerts can be configured for memory and drives
B. Redundancy status alerts can be configured for the CPU and the Smart Array controller
C. Redundancy status alerts can be configured for fans and the Smart Array controller
D. Pre-failure alerts can be configured for the CPU and the Smart Array controller
Answer: A
NO.6 Witch feature provides a customer alert to prevent a counterfiet hard drive from getting
installed in
an HP Proliant Gen8 server?
A. Drive error log NVRAM
B. Smart carrier authentication
C. Enhanced display
D. Smart array advanced pack
Answer: B
HP HP0-S34 (Implementing HP Rack and Tower Server Solutions) 덤프공부가이드
Posted 2013/5/30 6:34:55 | Category: 미분류 | Tag: