IT인증,IT자격증,IT자격증시험,IT인증시험

http://www.pass4test.net/

Cisco Specialist 642-995 시험덤프공부

Pass4Test에서 출시한 Cisco Specialist 642-995 (Unified Computing Troubleshoot) 덤프는  Cisco Specialist 642-995 (Unified Computing Troubleshoot) 시험에 대비하여 IT전문가들이 제작한 최신버전 공부자료로서 시험패스율이 100%입니다.Pass4Test는 고품질 Cisco Specialist 642-995 (Unified Computing Troubleshoot) 덤프를 가장 친근한 가격으로 미래의 IT전문가들께 제공해드립니다. Pass4Test의 소원대로 멋진 IT전문가도 거듭나세요.




NO.1 In a fully provisioned Cisco UCS 5108 chassis, how many fan modules are present?

A. 2

B. 4

C. 6

D. 8

Answer: D




NO.2 What information is recorded in the system event log?

A. split-brain status

B. VLAN membership

C. over- and under-voltage

D. high-availability status

Answer: C




NO.3 In order to perform a SAN boot, which entry should be located in the FCNS database?

A. Initiator

B. Target

C. Any E Ports in the data path

D. Both the Initiator and the Target

Answer: D




NO.4 During an attempted SAN boot, ROM BIOS fails and reports failure to find the configured LUN. Which

is the mostly likely cause?

A. The service profile has incorrectly configured Ethernet interfaces.

B. The service profile has incorrect LUN ID.

C. The Cisco UCS cluster is in NPV mode rather than switch mode.

D. The Cisco UCS cluster is in EHV mode rather than switch mode.

Answer: B




NO.5 By default, how long are cleared faults retained in the fault log?

A. 10 minutes

B. 1 hour

C. 3 minutes

D. 24 hours

Answer: B




NO.6 What is the over-subscription ratio of a fully populated Cisco UCS 5108 chassis with four fabric

connections per I/O module?

A. 1:1

B. 2:1

C. 3:1

D. 4:1

Answer: B




NO.7 After connecting to an M71KR server adapter, which command displays the adapter ¯ s v if s WW N s?

A. show server-profile circuit server

B. show-vifs

C. show interface

D. show fex detail

Answer: B




NO.8 After a memory upgrade, a customer ¯ s se r ve r f a il s t o boo t. W h i ch o f t he f o ll o w i ng cou l d cause a se r ve r

to be unable to boot?

A. a correctable ECC DIMM error

B. a non-correctable ECC DIMM error

C. a correctable ECC DIMM error that exceeds the error rate threshold

D. a degraded DIMM

Answer: B




NO.9 Which operation is most likely to cause the corruption of an I/O module?

A. improper firmware upgrade

B. improper transition to EHV mode

C. improper transition to Fibre Channel switch mode

D. FULL state backup

Answer: A




NO.10 Which command displays the transport (Ethernet, Fibre Channel) used by a virtual interface?

A. show fex detail

B. show service-profile circuit server x/y

C. show pinning server-interface

D. show pinning border-interface

Answer: B




NO.11 Which policy type can be configured to monitor motherboard temperature?

A. threshold policies

B. maintenance policies

C. power control policies

D. BIOS policies

Answer: A




NO.12 Which command can be run on an upsteam Cisco MDS switch to determine if a virtual Fibre Channel

interface has successfully logged into the fabric?

A. show zoneset active

B. show fcdomain domain-list

C. show vsan database

D. show npiv status

Answer: A




NO.13 A Cisco UCS cluster has two four-link I/O module connections to a single chassis. Server 8 is

provisioned with an M72-KR mezzanine card, which is pinned to I/O module Port 4. If I/O module Port 4

fails, what happens to the Ethernet traffic flow that is transmitted by Server 8.?

A. The traffic flow fails over to the second fabric interconnect.

B. The traffic flow stops until an administrator takes corrective action.

C. The traffic will be re-pinned to a different port on the same I/O module.

D. The traffic will utilize the cluster ports to flow between the initiator and the target.

Answer: B




NO.14 A chassis has all four I/O module ports connected but only one is being used. Which action will establish

full functionality to all four ports?

A. Enable the connecting ports on the upstream fabric interconnect.

B. Reacknowledge the chassis.

C. Reboot the affected servers.

D. Disable and re-enable the I/O module ports.

Answer: B




NO.15 Which tool can be used to view server temperature sensors?

A. SoL

B. dmidecode

C. IPMI

D. SPAN

Answer: C







Posted 2014/4/9 13:37:27  |  Category: cisco  |  Tag: 642-995 시험덤프공부