IT인증,IT자격증,IT자격증시험,IT인증시험

http://www.pass4test.net/

HP HP2-K36 (Support and Service HP StoreVirtual Solutions) 시험덤프공부

HP HP2-K36 (Support and Service HP StoreVirtual Solutions) 시험패스 공부방법을 찾고 있다면 제일 먼저 Pass4Test를 추천해드리고 싶습니다.HP HP2-K36 (Support and Service HP StoreVirtual Solutions) 시험이 많이 어렵다는것은 모두 알고 있는 것입니다. Pass4Test에서 출시한 HP HP2-K36 (Support and Service HP StoreVirtual Solutions) 덤프는 실제시험을 대비하여 연구제작된 멋진 작품으로서 HP HP2-K36 (Support and Service HP StoreVirtual Solutions) 시험적중율이 최고입니다. HP HP2-K36 (Support and Service HP StoreVirtual Solutions) 시험패스를 원하신다면 Pass4Test의 제품이 고객님의  소원을 들어줄것입니다.

 

 

NO.1 Which statements are correct about how Recovery Manager is used to recover data from

snapshots? (Select two.)

A. It is a cluster-aware application that will automatically failover to other servers.

B. It does not allow Linux / Unix formatted snapshots to be mounted.

C. It supports SmartClone and Remote Copy Snapshots.

D. It supports a total of five snapshots per volume to be mounted.

E. It allows iSCSI and Fibre Channel attached volumes to be restored.

Answer: D

 

 

NO.2 A media and broadcasting customer has an HP StoreVirtual 4000 Storage environment with

eight 4530 SAS nodes. Approximately 50% of the I/O is large sequential; therefore, the configuration

is set for maximum performance. After replacing a defective network switch, the customer

experiences performance and connectivity issues and asks you to solve the problem.

What should you investigate first?

A. If jumbo frames are enabled on the whole path

B. If Spanning Tree Protocol (STP) is enabled

C. If Active/Passive (A/P) bonding is enabled

D. If the switch has the actual firmware installed

Answer: A

 

NO.3 You have just completed the initial configuration of an HP StoreVirtual 4000 Storage cluster

What can you use to check for potential configuration issues such as improper NIC teaming, data

protection with Network RAID, and optimum load balancing across nodes in the cluster?

A. Insight Remote Support

B. SAN Health Page

C. SAN IQ Health check

D. Best Practice Analyzer

Answer: D

 

 

NO.4 In the event of a site failure in a multi-site configuration that is configured according to HP

best practices, how does the HP StoreVirtual 4000 Storage system handle the failover and tailback

process?

A. Failover is automatic, but fallback is manual.

B. Failover is automatic, but failback requires additional scripting.

C. Failover and failback are both manual processes.

D. Failover and failback are completely automatic.

Answer: D

 

NO.5 Which statement about Remote Copy is true?

A. The CMC software always deletes the last fully synchronized remote snapshot after creation.

B. It is a synchronous replication of data to a machine in a geographically-separate location.

C. If the network link goes offline during the process, copying resumes where it left off when the link

is restored.

D. A remote volume can be rolled back until you convert the remote volume into a primary volume.

Answer: B

 

 

NO.6 A large healthcare customer wants to implement an HP StoreVirtual 4000 Storage solution.

The customer has two fire zones within the main data center and needs 24x7 availability with

maximum data redundancy. The customer plans to implement an HP StoreVirtual 4000 Storage

solution that is distributed across the fire zones.

Which Network RAID configuration should you recommend to meet these requirements?

A. Network RAID 50+1

B. Network RAID 60+2

C. Network RAID 10+2

D. Network RAID 10+1

Answer: D

 

 

NO.7 Which functionality was introduced with HP LeftHand OS 10.x?

A. Windows Server 2008

B. Active Directory

C. FCoE

D. Quad CPU support for VSA

Answer: B

 

 

NO.8 You notice an error icon on a storage system in the navigation tree in the CMC. From the

server the CMC is running on, you can successfully ping the IP address of the storage system. What

is the most likely cause of this problem?

A. The management process is not responding.

B. The license for the storage node has expired.

C. The storage node has locked up.

D. The storage node was not assigned a name during installation.

Answer: B

 
Posted 2013/11/14 7:47:30  |  Category: 미분류  |  Tag: