Cisco 350-080 (CCIE Data Center Written Exam) 기출문제

Pass4Test  제공 Cisco 350-080 (CCIE Data Center Written Exam) 시험덤프자료가 광범한 시험준비인사들의 찬양을 받은지 하루이틀일이 아닙니다.이렇게 많은 분들이Pass4Test  제공 Cisco 350-080 (CCIE Data Center Written Exam) 덤프로 시험을 통과하여 자격증을 취득하였다는것은 Pass4Test  제공 Cisco 350-080 (CCIE Data Center Written Exam) 덤프가 믿을만한 존재라는것을 증명해드립니다. 덤프에 있는 문제만 열심히 공부하시면 시험통과 가능하기에 시간도 절약해줄수있어 최고의 믿음과 인기를 받아왔습니다. Cisco 350-080 (CCIE Data Center Written Exam) 시험을 봐야 하는 분이라면 Pass4Test를 한번 믿어보세요. Pass4Test도움으로 후회없이 멋진 IT전문가로 거듭날수 있을것입니다.







NO.1 Refer to the exhibit.

A port profile is created in the VSM, but it is
not seen in vCenter and cannot be assigned to a virtual

machine. Given the
configuration in the exhibit, which VSM command will resolve this issue?

A.
vmware port-group

B. vmware port-active

C. profile-active

D. port-group
active

E. shutdown / no shutdown

Answer: A



NO.2 How many VSM modes
are there in a Cisco Nexus 1000V environment?

A. 0

B. 1

C. 2

D.
3

E. 4

F. 5

Answer: D



NO.3 Which statement about the FCIP Tape
Acceleration feature is true?

A. Cisco MDS SAN-OS provides only tape write
acceleration.

B. After receiving all the data, the host-side MDS FCIP Tape
Acceleration-enabled switch proxies the

successful completion of the SCSI
WRITE operation.

C. Cisco SAN-OS provides increased performance of data
delivery to the remote FCIP connected tape

drives by using UDP over the
WAN.

D. The FCIP Tape Acceleration feature can be used with multilink port
channels if the port channels

are constructed with a port channel
protocol.

E. WRITE FILEMARKS operations are proxied by the host-side MDS FCIP
Tape Acceleration-enabled

switch.

Answer: B



NO.4 Which feature must
be enabled on the upstream Fibre Channel switch if the fabric interconnect

is
configured in end-host mode?

A. NPV

B. NPIV

C. Zoning

D. Smart
Zoning

Answer: B



NO.5 Which option is a benefit of virtualized
Application Networking Manager?

A. Static workload scaling

B. Local
authorization

C. High availability

D. Health monitor probe

E.
Distributed backup

Answer: D



NO.6 Which three statements best describe
multicast operation on Cisco Nexus switches in a data

center? (Choose
three.)

A. Cisco NX-OS Software does not support PIM dense mode.

B. The
command ip multicast-routing must be enabled in Cisco NX-OS Software before any
multicast

configuration is possible on the switch.

C. PIM CLI
configuration and verification commands are not available until you enable the
PIM

feature with the feature pim command.

D. Cisco NX-OS Software supports
multicast routing per Layer 3 VRF instance.

E. The default PIM operational
mode on the Cisco Nexus 7000 switch is SSM.

Answer: A,C,D



NO.7 What is
the appliance port used to connect to in a Cisco Unified Computing System?

A.
Fibre Channel storage

B. UCS C-Series servers

C. NFS storage

D. UCS
chassis

E. Other fabric interconnect

Answer: C



NO.8 In a Cisco
Unified Computing System, where are SAN port channels connected to?

A. Only
to Cisco Fibre Channel switches

B. Only to Cisco Fibre Channel switches in
NPIV mode

C. To any Fibre Channel switch

D. Directly to storage
arrays

E. Only to Nexus Switches

Answer: A