IT인증,IT자격증,IT자격증시험,IT인증시험

http://www.pass4test.net/

Motorola Solutions Certification MSC-241덤프자료

인재가 넘치는 IT업계에서 자기의 자리를 지켜나가려면 학력보다 능력이 더욱 중요합니다.고객님의 능력을 증명해주는 수단은 국제적으로 승인받은 IT인증자격증이 아니겠습니까? Motorola Solutions Certification MSC-241시험이 어렵다고 하여 두려워 하지 마세요. IT자격증을 취득하려는 분들의 곁에는 Pass4Test가 있습니다. Pass4Test의  Motorola Solutions Certification MSC-241시험준비를 하시고 시험패스하여 자격증을 취득하세요. 국제승인 자격증이라 고객님의 경쟁율을 업그레이드 시켜드립니다.

 

 

NO.1 What changes are required to the Master Repeater in an IP Site Connect system when a new

peer

is added to the system?

A. Both the IP address and port number of the new repeater must be configured into the Master

Repeater.

B. The address of the new peer must be configured into the Master Repeater.

C. The port of the new peer must be configured into the Master Repeater.

D. No changes are required to the Master Repeater.

Answer: D

 

NO.2 Which of the following antennas is BEST suited for providing coverage inside a tall building?

A. 4 element Yagi

B. Radiating coaxial cable

C. End-fed half-wave antenna

D. High gain collinear antenna

Answer: B

 

NO.3 A MOTOTRBO repeater is connected to a Zetron Model 35 Telephone Interconnect. If a

telephone

user dials the Telephone Interconnect number, they get a busy signal (engaged tone). If a radio

user dials any telephone number, they don’t hear the ringing tone, only silence. Upon visiting the

site, you find that when a radio user dials, the relay click can be heard from the Zetron Model 35.

Unplugging the RJ11 and dialing the Telephone Interconnect, still results in a busy signal

(engaged tone). With this information, what do you think could be wrong?

A. The Zetron Model 35 may be faulty.

B. The Zetron Model 35 has probably not been configured for the phone line Ringer Equivalence

Number (REN).

C. The RJ11 cable may have a short circuit or there is a short circuit somewhere between the site

and the exchange.

D. The repeater interface cable to the Zetron Model 35 is faulty.

Answer: C

 

NO.4 What will Enhanced Channel Access improve?

A. The amount of GPS updates that can be sent on a data revert channel

B. The amount of time from when PTT is pressed until voice is sent

C. Call success rate

D. Call setup time

Answer: C

 

NO.5 You are looking to optimize battery life of radios that are close to the base station. Which is

the

most likely parameter for optimizing the battery life of a radio for a Capacity Plus system?

A. Beacon interval

B. Beacon duration

C. High power mode in Radio

D. Low power mode in Radio

Answer: D

 

NO.6 A Capacity Plus system consists of three (3) repeaters with repeater one (1) the master and

repeaters two (2) and three (3) as peers. On the 24th of May, there is a lighting strike at the site

and the building lost power, causing the three repeaters to revert to DC power. The design of the

site called for just the repeaters to be battery backed. However the next morning the customer

calls and reports that a number of talkgroups are getting busy tones (engaged), yet other groups

are seeing no busy tones (engaged) on the system. Which of the following statements BEST

describe the issue?

A. The master has gone down and taken the rest of the Capacity Plus network with it.

B. The peers use DHCP and were not able to connect to the master and refresh their peer list and

went off the Capacity Plus network as their leases expired.

C. The switch was not on battery backup and there are no LAN connections on the Capacity Plus

system, each of the repeaters are now operating as three (3) independent Capacity Plus systems.

D. The peers use DHCP and were not able to connect to the master and refresh their peer list.

The dealer should have used static IP addresses throughout.

Answer: C

 

NO.7 A Capacity Plus system consists of three (3) repeaters with repeater one (1) the master and

repeaters two (2) and three (3) as peers. The dealer needs to make a simple change in repeater

two (2) and utilize IP repeater programming (IRP) to access the repeater remotely. A couple of

days later the customer calls and complains about users getting system busy tones (engaged

tones).

The dealer attempts to connect an RDAC remotely to the system with no success. He has verified

he can communicate to the router at the site.

Which of the following statements BEST describes the issue?

A. The master has gone down and taken the rest of the Capacity Plus network with it.

B. The master has gone down and the system is operating on just two (2) repeaters.

C. There is RF interference on the channel and the master repeater is unable to communicate to

the peers.

D. The peers are using DHCP and are not able to connect to the master and refresh their peer list.

The system is operating on just the master.

Answer: B

 

NO.8 Which of the following are TRUE statements about operating a MOTOTRBO repeater in an IP

Site

Connect configuration?

A. One of its logical channels can work in IP Site Connect mode (over wide area) and the other

logical channel can work in digital repeater mode (single site over local area).

B. Both logical channels can work in digital repeater mode (single site over local area).

C. Both logical channels can work in IP Site Connect mode (over wide area).

D. Only A and B are true (C is false).

E. Only A and C are true (B is false).

F. A, B, and C are true.

Answer: F

 

NO.9 On which type of channel in an IP Site Connect system are Transmit Interrupt features

supported

in repeater firmware releases R01.08.00 and higher?

A. Wide Area Slots only

B. Local Area Slots only

C. Both Wide and Local Area slots

D. Noneoftheabove

Answer: D

 

NO.10 Which of the following are TRUE statements about operating a MOTOTRBO repeater in a

Capacity Plus configuration?

A. One of its logical channels can work in trunked mode and the other logical channel can work in

data revert mode.

B. Both logical channels can work in trunked mode.

C. Both logical channels can work in data revert mode.

D. Only A & B are true (C is false)

E. Only B & C are true (A is false)

F. A, B, & C are true

Answer: F

 

 

 
Posted 2013/6/7 8:39:31  |  Category: 미분류  |  Tag: