NO.1 A customer is planning to consolidate server workloads to multiple partitions running on an

8-core

Power 720 system. They also need to support virtual storage for Windows workload running in a

BladeCenter and AIX and Linux partitions. Which of the following supports virtual storage for

Windows servers?

A. IBM i

B. Virtual I/O Server

C. PowerVM Express Edition

D. VMControl Entry Edition

Answer: A

 

NO.2 Which of the following is a difference between the Power 720/740 Host Ethernet Adapter

(HEA)

and the Power 520 Integrated Virtual Ethernet (IVE) adapter?

A. Supports 1Gbps speeds

B. Available as a MES

C. Support for RJ-45 ports

D. Supports port virtualization

Answer: D

 

NO.3 What is a capability of the IBM Workload Estimator?

A. It can plan for VIOS for IBM i.

B. It converts system plans generated by HMC.

C. It can validate plans for initial ordering.

D. It provides input to the System Planning Tool.

Answer: D

 

NO.4 Which of the following provides the most capacity and satisfies the disk and write cache

protection

rules for IBM i 7.1 when running on a POWER Blade in a BladeCenter S?

A. Mirror the disks using IBM

B. Mirror the disks using VIOS *

C. RAID-5 with two BladeCenter S SAS RAID Controller Modules

D. RAID-5 with a single BladeCenter S SAS RAID Controller Module

Answer: B

 

NO.5 How does the N-2 rule apply when upgrading to IBM i 7.1?

A. A compatibility PTF is required when upgrading from 5.3

B. Two full system saves must be done before upgrading to 7.1.

C. i 5.4 is the oldest version that can upgrade directly to 7.1.

D. MES hardware upgrade must be installed before upgrading to 7.1.

Answer: C

 

NO.6 A customer is running a mission critical application on an older POWER6 520 system. They

want

to upgrade to the Power 720 server but leave the application and data on the existing disks. What

is required to meet the customer needs?

A. HSL-2 I/O drawer

B. FC #5796 I/O drawer

C. FC #5877 I/O drawer

D. Olddisks moved to the new server

Answer: D

 

NO.7 A customer is running on a 2-core POWER6 520 server and IBM i 6.1. The server hardware

needs

to be upgraded for performance and additional memory capacity. Upgrading to which Power

Systems server will enable this customer to keep the serial number from the 520?

A. Power 740 4-core

B. Power 720 4-core

C. Power 730 8-core

D. Power 720 6-core

Answer: D

 

NO.8 Which IBM SAN is supported on BladeCenter S for IBM i, Linux and AIX ?

A. XIV

B. DS3200

C. DS3400

D. DS4800

Answer: B

 

 