IT인증,IT자격증,IT자격증시험,IT인증시험

http://www.pass4test.net/

HP Certification III HP0-S34 시험덤프공부가이드

HP Certification III HP0-S34 시험준비를 하고 계시다면 Pass4Test에서 출시한  HP Certification III HP0-S34 덤프를 제일 먼저 추천해드리고 싶습니다. Pass4Test제품은 여러분들이 제일 간편한 방법으로 시험에서 고득점을 받을수 있도록 도와드리는 시험동반자입니다.HP Certification III HP0-S34 시험패는 Pass4Test제품으로 고고고!



NO.1 You are installing HP insight Control for Microsoft system Center on a customer site. You want

to

be able to use System Center Configuration Manager to install HP ProLiant drivers and firmwares

using a rules based model. Which component should be installed?

A. HP Proliant Pro Management Kit

B. HP Proliant Update Catalog

C. HP Proliant OS deployment Toolkit

D. HP Proliant Agent less Management Kit

Answer: B


NO.2 A customer wants to build an HPC cluster and needs the highest performance and bandwidth.

What should he used?

A. Flex 10

B. 10 GB Ethernet

C. Flex Fabric

D. FDR InfiniBand

Answer: D


NO.3 In HP Systems Insight Manager version 7 and beyond, which new tools can be used for

baselining? (Select two)

A. Track software and firmware versions

B. Manage software and firmware baselines

C. Manage hardware and software versions

D. Track hardware and software baselines

E. Track driver and firmware baselines

Answer: A,B


NO.4 You are planning to install an HP DL380 Gen8 server at a customer site. The customer wants to

use the HP Agentless management functionality. Which statement is correct when implementing

this management solution?

A. Pre-failure alerts can be configured for memory and drives

B. Redundancy status alerts can be configured for the CPU and the Smart Array controller

C. Redundancy status alerts can be configured for fans and the Smart Array controller

D. Pre-failure alerts can be configured for the CPU and the Smart Array controller

Answer: A


NO.5 Witch feature provides a customer alert to prevent a counterfiet hard drive from getting

installed in

an HP Proliant Gen8 server?

A. Drive error log NVRAM

B. Smart carrier authentication

C. Enhanced display

D. Smart array advanced pack

Answer: B


NO.6 After configuring the bare metal HP Agentless Management, the customer notices that not all

system information is display. In addition, to system information displayed with the bare metal

method, which information can be collected when running HP Agentless Management. (Choose

Two)

A. Storage firmware

B. Network firmware

C. Power an cooling information

D. Processor data

E. Memory information

Answer: C,E



Posted 2013/5/30 6:36:54  |  Category: 미분류  |  Tag: