IT인증,IT자격증,IT자격증시험,IT인증시험

http://www.pass4test.net/

Symantec 250-253최신버전덤프

Symantec 250-253 (Administration of Veritas Cluster Server 6.0 for Unix ) 시험을 통과하여 자격증을 취득하여 IT 업계에서의 자신의 자리를 지키려면 많은 노력이 필요합니다. 회사일도 바쁜데 시험공부까지 스트레스가 장난아니게 싸이고 몸도 많이 상하겠죠. Pass4Test는 여러분을 위해 최신  Symantec 250-253 (Administration of Veritas Cluster Server 6.0 for Unix ) 시험에 대비한  Symantec 250-253 (Administration of Veritas Cluster Server 6.0 for Unix ) 덤프를 발췌하였습니다. Symantec 250-253 (Administration of Veritas Cluster Server 6.0 for Unix ) 덤프는  Symantec 250-253 (Administration of Veritas Cluster Server 6.0 for Unix ) 시험의 기출문제와 예상문제가 묶어져 있어 시험적중율이 굉장히 높습니다. 쉽게 시험을 통과하려면 Pass4Test의 Symantec 250-253 (Administration of Veritas Cluster Server 6.0 for Unix ) 덤프를 추천합니다.





NO.1 Which two triggers can only be enabled at the resource level? (Select two.)


A. Resrestart


B. Resadminwait


C. Resfault


D. Resstatechange


E. resnotoff


Answer: B,E





NO.2 Which two actions can be taken to determine whether an application clustered with Veritas Cluster


Server (VCS) has been successfully started or stopped? (Select two.)


A. examine the online log file


B. examine the engine log file


C. view the Security Log from the VCS Java GUI


D. view the Log Desk from the VCS Java GUI


E. view the Application_A.log file


Answer: B,D





NO.3 Which type of resources are considered by Veritas Cluster Server when determining whether a service


group is online?


A. OnOnly


B. OnOff


C. Persistent


D. None


Answer: B





NO.4 Which two actions must be taken to upgrade an application under Veritas Cluster Server control?


(Select two.)


A. verify that the application agent supports the new version


B. verify that the new version is supported with haagent verify


C. freeze the application service group


D. freeze the application resources


E. stop the application agent on all systems


Answer: A,C





NO.5 When architecting Coordination Point (CP) server into a Veritas Cluster Server (VCS) environment,


what should be done to ensure the CP service remains online?


A. configure multiple CP server instances on the same node


B. configure CP server as a resource in a VCS cluster


C. ensure that the CP server is backed up regularly


D. ensure that the CP server is on a reliable network


Answer: B





NO.6 You have removed a system from a running Veritas Cluster Server cluster so that the cluster now only


has seven nodes. You need to ensure the cluster will start successfully after a complete cluster shutdown.


Which line should be in the /etc/gabtab file to successfully start the cluster?


A. gabconfig -c -n 7


B. clust start seed=7


C. gabconfig start seed=7


D. clust -c -n 7


Answer: A





NO.7 One of the three coordinator disks needs to be repurposed as a data disk. What can the administrator


do to accommodate growth in the data center and still provide SCSI-3 I/O fencing?


A. use gatekeeper LUNs to provide additional coordinator disks


B. replace all coordinator disks with Coordination Point servers


C. remove a coordinator disk from the cluster and replace it with a Coordination Point server


D. use compressed disks to double the space available for coordinator disks to enable future growth


Answer: C





NO.8 In a four-node cluster configuration, main.cf is modified to remove one of the four nodes. That node is


decommissioned, and the remaining cluster configuration is unchanged. A power failure causes all three


remaining nodes to shut down. What happens when all three nodes are powered on.?


A. The three nodes form a cluster.


B. Veritas Cluster Server will need manual intervention to come online.


C. LLT will fail because the fourth node is in the llthosts.


D. Veritas Cluster Server will go into ADMIN_WAIT.


Answer: B



Posted 2014/6/4 10:50:45  |  Category: Symantec  |  Tag: 250-253최신버전덤프