BICSI RCDD 최신덤프

Pass4Test 에서 출시한 BICSI RCDD (Registered Communications Distribution Designer ) 시험덤프는 100%시험통과율을 보장해드립니다. 엘리트한 IT전문가들이 갖은 노력으로 연구제작한  BICSI RCDD (Registered Communications Distribution Designer ) 덤프는 PDF버전과 소프트웨어버전 두가지 버전으로 되어있습니다. 구매전 PDF버전무료샘플로Pass4Test제품을 체험해보고 구매할수 있기에 신뢰하셔도 됩니다. BICSI RCDD (Registered Communications Distribution Designer ) 시험불합격시 불합격성적표로 덤프비용을 환불받을수 있기에 아무런 고민을 하지 않으셔도 괜찮습니다.

 

 

NO.1 A "wye" is a power system in which only one point is grounded.

A. False

B. True

Answer: B

 

NO.2 ANSI/TIA/EIA-758 is the standard for which of the following?

A. Customer-Owned Outside Plant Telecommunications Cabling Standard.

B. Technical Specifications for 100 Ohm Screened Twisted Pair Cabling.

C. Propagation Delay and Delay Skew Specifications for 100-Ohm 4-Pair Cable.

D. Residential Telecommunications Cabling Standard.

Answer: A

 

NO.3 The inadvertent transposition of two conductors of separate pairs is called what?

A. Twisted pair

B. Transposed pairs

C. Reversed pair

D. Split pair

Answer: D

 

NO.4 What is the standard floor space allocation used in an office environment for one

individual work area?

A. 100 square feet.

B. 50 square feet.

C. 150 square feet.

D. 75 square feet.

Answer: A

 

NO.5 Distribution cable is that part of the loop that connects the customer location to the

customer feeder cable.

A. True

B. False

Answer: A

 

NO.6 In buildings that will contain the telecommunications systems, NEC requirements

address the adequate electrical environment for reliable and error-free operation of

the installed equipment.

A. False

B. True

Answer: A

 

NO.7 In what year was the TIA formed?

A. 1985

B. 1965

C. 1958

D. 1956

Answer: A

 

NO.8 The ability of a device, equipment, or system to perform without degradation in the

presence of an electromagnetic disturbance is called what?

A. Electromagnetic immunity.

B. Electromagnetic compatibility.

C. Electromagnetic induction.

D. Electromagnetic disturbance.

Answer: A

 

NO.9 ________is the total opposition (resistance, capacitance, and inductance) a circuit,

cable, or component offers to the flow of alternating current.

A unit of measure expressed in ohms.

Answer: Impedance

 

NO.10 Which of the following is the international standard for premises cabling?

A. ISO/IEC 18010

B. ISO/IEC 11801

Answer: B

 

NO.11 In an "underfloor duct system", the distribution ducts carry cables from the TR to

the feeder ducts.

A. False

B. True

Answer: A

 

NO.12 Between the late 60's and until 1984, what was the service that was to help architects

and engineers better design and implement pathways and spaces in commercial

buildings for telephone communications?

A. BICS

B. AT&T

C. CREDFACS

D. GTE

E. BICSI

Answer: A

 

NO.13 NRZ is the acronym for which of the following?

A. Non-return to zero.

B. Nominal return zone.

C. Network registration zone.

D. Normal return zone.

Answer: A

 

NO.14 Which of the following is the Standard for the Installation of Lightning Protection

Systems?

A. NFPA-780

B. NFPA-70

C. NFPA-72

D. NFPA-75

Answer: A

 

NO.15 The CEC is revised every four years.

A. True

B. False

Answer: A

 

NO.16 A product is listed after it successfully completes a series of which of the following

test?

A. Mechanical

B. Regulatory codes

C. Electrical

D. Thermal

Answer: ACD

 

NO.17 Which of the following is the standard for "Recommended Practice for Installation

Design and Installation of Valve Regulated Lead-Acid Storage Batteries for

Stationary Applications"?

A. ANSI/IEEE C62.41

B. ANSI/IEEE C62.45

C. ANSI/IEEE P1188-1996

D. ANSI/IEEE P1187-1996

Answer: D

 

NO.18 Which of the following should be used as a guideline for estimating space

requirements of optical fiber and coaxial cable cross-connections in a TR?

A. 3 sq. in. for each fiber pair to be patched or cross-connected.

B. 2 sq. in. for each fiber pair to be patched or cross-connected.

C. 4 sq. in. for each fiber pair to be patched or cross-connected.

D. 1 sq. in. for each fiber pair to be patched or cross-connected.

Answer: B

 

NO.19 Which of the following is the Cable Modem (Cable-TV) Working Group?

A. IEEE 802.9

B. IEEE 802.11

C. IEEE 802.14

D. IEEE 802.3

Answer: C

 

NO.20 For design purposes, which of the following would be the typical size range of a

4-pair 100 ohm UTP or ScTP (FTP) cable?

A. .50 in to .75 in

B. .14 in to .25 in

C. .31 in to .43 in

D. .11 in to .18 in

Answer: B

 

 