IT인증,IT자격증,IT자격증시험,IT인증시험

http://www.pass4test.net/

IBM Certified Specialist 000-781 (PureFlex Technical Support V1) 덤프자료

Pass4Test는 여러분들한테 최고의  IBM Certified Specialist 000-781 (PureFlex Technical Support V1)문제와 답을 제공함으로  높은 적중율을 자랑합니다, 여러분은  IBM Certified Specialist 000-781 (PureFlex Technical Support V1)인증시험의 패스로 IT업계와  직장에서 한층 업그레이드 되실수 있습니다. 여러분의 미래는 더욱더 아름다울 것입니다. IBM Certified Specialist 000-781 (PureFlex Technical Support V1)시험의 인기는 날마다 더해갑니다. IBM Certified Specialist 000-781 (PureFlex Technical Support V1)시험에 응시하는 분들도 날마다 더 많아지고 있습니다. IBM Certified Specialist 000-781 (PureFlex Technical Support V1)인증시험 준비중인 여러분은 어떤 자료를 준비하였나요?Pass4Test는 전문적인 IT인증시험덤프를 제공하는 사이트입니다. IBM Certified Specialist 000-781 (PureFlex Technical Support V1)인증시험을 패스하려면 Pass4Test을 선택하시면 아주 현명한 선택입니다. Pass4Test에서는  IBM Certified Specialist 000-781 (PureFlex Technical Support V1)관련 자료도 제공함으로 여러분처럼 IT 인증시험에 관심이 많은 분들한테 아주 유용한 자료이자 학습가이드입니다. Pass4Test는 여러분이 원하는 최신 최고버전의  IBM Certified Specialist 000-781 (PureFlex Technical Support V1)문제와 답을 제공합니다.  IBM Certified Specialist 000-781 (PureFlex Technical Support V1)인증덤프는 IT업계전문가들이 끊임없는 노력과 지금까지의 경험으로 연구하여 만들어낸 제일 정확한 시험문제와 답들로 만들어졌습니다. Pass4Test의 문제집으로 여러분은 충분히 안전이 시험을 패스하실 수 있습니다. 우리 Pass4Test 의 문제집들은 모두 100%합격율을 자랑하며 Pass4Test의 제품을 구매하였다면    IBM Certified Specialist 000-781 (PureFlex Technical Support V1)관련 시험패스와 자격증 취득은 근심하지 않으셔도 됩니다. 여러분은 IT업계에서 또 한층 업그레이드 될것입니다.

 

 

NO.1 A PureFlex prospect is concerned about rack capacity on their single rack configuration. Which of the
following is the maximum number of PureFlex chassis that fit in this configuration?
A. 2
B. 3
C. 4
D. 5
Answer: B

NO.2 Power Systems compute nodes communicate over the management network through which controller?
A. Flexible Service Processor (FSP)
B. Integrated Virtualization Management (IVM)
C. Integrated Management Module v1 (IMMv1)
D. Integrated Management Module v2 (IMMv2)
Answer: A

NO.3 Design criteria dictates the use of SAN pass-thru now and the ability to upgrade to full fabric capability
later. Which of the following is the most cost effective way to accomplish this?
A. Select the 8Gb SAN Switch module now and enable full fabric functionality later
B. Select the 8Gb SAN Pass-thru module now and enable full fabric functionality later
C. Select the 8Gb SAN Switch module now and switch to Brocade interoperability mode later
D. Select the 8Gb SAN Pass-thru module now and convert to full functionality through activation codes
later
Answer: A

NO.4 A customer is discussing PSU redundancy alternatives. Which is an advantage of N+1 over N+N for
PSU redundancy?
A. Better PSU redundancy
B. Possible lower amperage circuits
C. Greater number of compute nodes supported
D. Chassis can be setup as a dual power domain
Answer: B

NO.5 A customer is moving their IBM i environment to PureFlex, and they want to know how they can attach
the V7000 disk. Which of the following is correct.?
A. IBM i only supports internal storage with PureFlex
B. Direct attached storage is an additional charge
C. IBM i attaches to storage through the VIO server
D. Direct attached storage is included in the system cost
Answer: C