IT인증,IT자격증,IT자격증시험,IT인증시험

http://www.pass4test.net/

Oracle 1z0-485 (Exadata Database Machine Models X3-2 and X3-8 Implementation Essentials) 덤프

Pass4Test  제공 Oracle 1z0-485 (Exadata Database Machine Models X3-2 and X3-8 Implementation Essentials) 시험덤프자료가 광범한 시험준비인사들의 찬양을 받은지 하루이틀일이 아닙니다.이렇게 많은 분들이 Pass4Test  제공 Oracle 1z0-485 (Exadata Database Machine Models X3-2 and X3-8 Implementation Essentials) 덤프로 시험을 통과하여 자격증을 취득하였다는것은 Pass4Test  제공 Oracle 1z0-485 (Exadata Database Machine Models X3-2 and X3-8 Implementation Essentials) 덤프가 믿을만한 존재라는것을 증명해드립니다. 덤프에 있는 문제만 열심히 공부하시면 시험통과 가능하기에 시간도 절약해줄수있어 최고의 믿음과 인기를 받아왔습니다.Oracle 1z0-485 (Exadata Database Machine Models X3-2 and X3-8 Implementation Essentials) 시험을 봐야 하는 분이라면 Pass4Test를 한번 믿어보세요. Pass4Test도움으로 후회없이 멋진 IT전문가로 거듭날수 있을것입니다.




NO.1 Consider the following software changes that are performed manually on a Linux server:

1.Changes for Linux kernel firewall configuration

2.Changes for custom performance monitoring tools

3.Changes for security scan tools

4.Changes for Linux system performance optimization

Which of the software changes listed are permitted on Exadata Storage Servers?

A. 1, 2, 3, and 4

B. only 3 '

C. none

D. only 2

E. only 1 and 2

F. only 2 and 3

Answer: E

Explanation:

1. The Storage Server Patch is responsible for keeping our cell nodes always up-todate, fixing

possible problems, and this patch includes different component patches, like kernel patches,

firmware, operation system, etc... for the Storage Server. Incorrect: 3,4: security scan tools changes

and Linux system performance optimization changes would be on the database server.




NO.2 A customer has three databases named CC. FIN, and DW. The CC database is for their

CallCenter. Even a slight decrease in the response time of the database would mean more people

"on hold" in their data center. The orders received through the CallCenter are stored in the Finance

(FIN) database. Both databases, CC and FIN, serve as sources for the Data Warehouse (DW)

database. All databases use the same Automatic Storage Management (ASM) diskgroup and

therefore, the same physical disks on Exadata storage. The customer wants to dynamically control

the resources that are available for the CallCenter database because this has direct impact on their

operations?

Which option should be implemented?

A. DBRM on the CC database

B. DBRM on all the databases

C. IORM, because DBRM cannot be changed for an existing session

D. IORM and DBRM

Answer: B

Explanation:

Using the Database Resource Manager, you can: Distribute available processing resources by

allocating percentages of CPU time to different users and applications. In a data warehouse, a

higher percentage may be given to ROLAP (relational on-line analytical processing) applications than

to batch jobs.




NO.3 Consider this CellCLI command:

CellCLI> CREATE GRIDDISK ALL HARDDISK PREFIX=data, size=423G;

Which two statements describe what happens when you execute this command?

A. It creates one 423 GB grid disk on the first available cell hard disk.

B. It creates one 423 GB grid disk on each available cell hard disk.

C. It creates grid disks on the outermost 423 GB that is available on each hard disk.

D. It creates grid disks on the innermost 423 GB that is available on each hard disk.

E. It creates an Exadata Smart Flash Cache on all flash drives.

Answer: B,C

Explanation:

* Example: CellCLI> create griddisk all harddisk prefix=temp_dg, size=570G This command will

create 12 Griddisks, each of 570G in size from the outer (fastest) sectors of the underlying Harddisks.

It fills up the first 2 Celldisks entirely, because they have just 570G space free - the rest is already

consumed by the OS partition.

8. You get a Host Unreachable error when you attempt to connect to a server through a network

terminal command line. What are two other ways in which you can connect?

A. Use the ILOM Web GUI.

B. Use the dcli command at the root prompt on a database node.

C. Attach a terminal device to the back panel of the server with a serial cable.

D. Connect by using SQL *Plus.

E. Log in as root on the database node using the Net1 IP address.

Answer: A,C

Explanation:

In addition to gaining shell access via SSH to manage your Exadata servers, you can also access them

from the Integrated Lights Out Management (ILOM) console or KVM console.

and should typically not require modifications unless you have changed network information inside

your database machine.

Note: A KVM switch (with KVM being an abbreviation for "keyboard, video and mouse") is a

hardware device that allows a user to control multiple computers from one or more[1] keyboard,

video monitor and mouse. Although multiple computers are connected to the KVM, typically a

smaller number of computers can be controlled at any given time

9. Identify three best practices for applying asmdeactivationoutcome es on Exadata Database

Servers and Exadata Storage Servers?

A. Backing up database servers and storage cells is not recommended before performing planned

maintenance.

B. Database server updates can be rolled back using the the "yum downgrade" procedure.

C. Bundle patches do not require testing before being installed on a production system.

D. It is recommended that Exadata systems with Data Guard configured use the "Standby First"

patching approach.

E. Patching should never be interrupted due to a connection drop. It is therefore recommended that

you use VNC or the screen utility.

F. Before patching cells in a rolling manner, you must check asmdeactivationoutcome amModestatus

and make sure that cells on all disks are online and that disks can be deactivated.

Answer: D,E,F

10. The mpstat output from OS Watcher shows a database node as being 90% idle on an average.

What would you do to get a full picture of CPU utilization on the entire Exadata RAC cluster?

A. Average the mpstat id1 output from all the nodes.

B. Ask application users if they have noticed a slowdown in screen response.

C. Look for an increase in batch job servicing times.

D. A & B above

Answer: A




NO.4 Which two statements are true about enabling write-back flash cache?

A. When enabling write-back flash cache in a non rolling manner, it is important to ensure that

asmdeactivatonoutcome is set to YES and asmModestatus is set to ONLINE for all grid disks.

B. Before using write-back flash cache, you need to verify the minimum required versions.

C. Before write back-flash cache is enabled, you need to drop the Flash Cache first.

D. The setting flashCacheMode should be set to writeback by updating cellinit.ora and restarting

cellsrv.

E. When enabling write-back flash cache in a rolling manner, dcli should be used to inactivate the

grid disks on all cells first.

Answer: B,C

Explanation:

B: Exadata storage version 11.2.3.2.1 is the minimum version required to use this write back flash

cache option.

C: Steps for Enabling Write back flash cache:

First of all, you don't need the stop CRS or database (This is ROLLING method) ,you can do it cell

by cell.

*drop flashcache

*Be sure asmdeactivationoutcome is YES is before disabling grid disk




NO.5 Consider the following setup:

User A1 belongs to resource group High on Database A.

User B2 belongs to resource group Low on Database B.

User C3 is a user on Database C without any DBRM setup.

DBRM setup:

Database A: Resource group High gets 80% and Low gets 20%.

Database B: Resource group High gets 60% and Low gets 40%.

IORM setup:

Database A: Share=20, limit=5

Database B: Share=30, limit=10

Database C: 5 shares

Total number of shares in the IORM setup = 100

What percent of I/O will each database user theoretically be using when the Exadata storage unit

I/O throughout is used 100% and no other databases but A, B, and C are running?

A. Al = 36%, B2=18%, and C3=9%

B. Al = 33%, B2=33%, and C3=33%

C. AI = 10%, B2=5%, and C3=20%

D. Al = 8%, B2=12%, and C3=5%

E. Al = 5%, B2=10%, and C3=85%

Answer: E

Explanation:

IORM setup limits Database A to 5%, and Database B is limited to 10%, while

Database C has not IORM limit.

Not that the resource groups are for CPU allocation.




NO.6 Exadata Database Machine offers an Intelligent Platform Management Interface for the

various components in the Exadata product. Which option is true?

A. IPMI can be used to remotely start and stop servers.

B. IPMI can be used to remotely log in to the operating system.

C. IPMI commands can be executed by using SNMP traps.

D. IPMI settings can be secured by backing up the Oracle Linux installation on the storage system.

Answer: A

Explanation:

IPMI - short for Intelligent Platform Management Interface - is an interface standard that allows

remote management of a server from another using standardized interface. The servers in the

Exadata Database Machine follow that. It's not an Exadata command but rather a general Linux one.

To power on a cell or database server, issue this from another server: # ipmitool -H prolcel01-ilom

-U root chassis power on

To stop a server, use the shutdown command. To stop immediately and keep it down, i.e. not reboot,

execute:# shutdown -h -y now




NO.7 Which is the best location to point your customer to, for finding the latest Exadata patches?

A. owner's guide

B. Patch database in MyOracle Support

C. MyOracle Support note 888828.1

D. MyOracle Support for database patches, ULN for OS patches, and Sun Support for Server and

InfiniBand patches.

Answer: B

Explanation:

Before starting, we would like to share and note here two documents from My Oracle Support, aka

metalink. These notes must be the first place that you need to go to review before patching the

Exadata environment.

* (B) Database Machine and Exadata Storage Server 11g Release 2 (11.2) Supported Versions (Doc ID.

888828.1)

-This is for the second and third generation (V2 and X2) for Oracle Exadata, using Sun hardware.

* Database Machine and Exadata Storage Server 11g Release 1 (11.1) Supported Versions (Doc

ID. 835032.1)

* - This is for the first generation (V1) for Oracle Exadata, using HP hardware.







Posted 2014/4/15 13:31:17  |  Category: Oracle  |  Tag: Oracle 1z0-485