CATE C4040-109 (Virtualization Technical Support for AIX and Linux - v2) 시험은 빨리 패스해야 되는데 어디서부터 어떻게 시험준비를 시작해야 하는지 갈피를 잡을수 없는 분들은 Pass4Test가 도와드립니다. Pass4Test의 CATE C4040-109 (Virtualization Technical Support for AIX and Linux - v2) 덤프만 공부하면 시험패스에 자신이 생겨 불안한 상태에서 벗어날수 있습니다.덤프는 시장에서 가장 최신버전이기에 최신 시험문제의 모든 시험범위와 시험유형을 커버하여 CATE C4040-109 (Virtualization Technical Support for AIX and Linux - v2) 시험을 쉽게 패스하여 자격증을 취득하여 찬란한 미래에 더 가깝도록 도와드립니다.

 

NO.1 An administrator must remove any installed efixes before attempting to install a new VIO Fix Pack.

Which VIO command will advise if any VIO efixes are actually present?

A. lslpp

B. emgr

C. lssw

D. oem_platform_level

Answer: C

 

NO.2 A Power 720 is being used to build 2 environments: Test and Production, with 2 LPARs in each

environment. Processor resources must be separated between the Test and Production environments to

reduce possible contention, while still being able to share processor resources inside each own

environment.

What are the two features required, as a minimum, to accomplish this? (Select 2)

A. IVM

B. HMC

C. PowerVM Express

D. PowerVM Standard

E. IVE

F. IBM Systems Director

Answer: B,D

 

NO.3 An administrator is attempting to configure a new deployment of 56 POWER7 Blades across 4 IBM

BladeCenter H chassis. Each blade will be installed with an IVM and 2 LPARs.IVM is installed and the

administrator checks that both LHEA ports are reporting a Link State of "Up." 2 LPARs are created and the

network traffic balanced by allocating one LHEA port to the first LPAR, the second port to the other. After

successfully installing the first LPAR via NIM, the administrator finds the second LPAR fails to netboot.

What should the administrator verify on the BladeCenter Chassis?

A. That 4 power supplies (PSU) have been installed.

B. That both the external LHEA ports have been cabled.

C. That a secondary I/O module has been installed and cabled.

D. That the Multi-Core Scaling (MCS) attribute is correctly set on both LHEA ports.

Answer: C

 

NO.4 Which of the following is required to support AME?

A. AIX LPARs

B. Virtual I/O Server

C. A maximum of 4GB of RAM per LPAR

D. On-demand memory feature enabled

Answer: A

 

NO.5 Requirements for a disaster recovery site are being collected. When considering restoring a VIO

Server mksysb to disaster recovery hardware,

what is required to ensure automatic virtual device recreation?

A. LPAR profiles must be accurately recreated on the foreign machine

B. Backups of both mksysb and user-defined structures are required from the VIO Server

C. The foreign machine must be of the same model and type

D. Configuration of the existing HMC needs to be preserved

Answer: A

 

NO.6 When attempting to install a VIO client using NIM, an adminstrator finds that no disks are available

for installation. The disks are provided by NPIV through the virtual Fibre Channel adapter as described

here:

Which of the following explains why is the administrator unable to see the disks?

A. The virtual fibre channel device has not been assigned to the client.

B. The HBA on the VIO server is not connected to the SAN.

C. The fibre device drivers are missing from the SPOT.

D. The LUNs have been incorrectly zoned.

Answer: D

 

NO.7 What tool can an architect use to determine which is the smallest POWER7 server that will provide

equal or better overall performance than a POWER5 570?

A. Facts and Features Guide

B. LPAR Validation Tool

C. Configurator for eBusiness

D. Server Magic

Answer: A

 

NO.8 An administrator has a requirement to back up a VIO server (VIOS) so that it can be rebuilt in the

event of a disaster.

Which set of actions will achieve this requirement.?

A. Backup all non rootvg volume groups using savevg. Backup all Storage Pool Information. Run a

mksysb of the system.

B. Save "Upgrade Data" on the HMC. Backup all non rootvg volume groups using savevg. Run a mksysb

of the VIOS with the -U flag.

C. Backup non rootvg structures using savevgstruct. Capture virtual mappings to a file using viosbr. Run a

backupios

D. Capture the virtual network tuning to a file using the optimizenet command. Capture all virtual device

attributes to a file using the lsattr command. Run a backupios.

Answer: C

 

 